Your browser doesn't support javascript.
Show: 20 | 50 | 100
Results 1 - 8 de 8
Filter
1.
Atmosphere ; 14(4):716, 2023.
Article in English | ProQuest Central | ID: covidwho-2297048

ABSTRACT

The risk of COVID-19 infection from virulent aerosols is particularly high indoors. This is especially true for classrooms, which often do not have pre-installed ventilation and are occupied by a large number of students at the same time. It has been found that precautionary measures, such as the use of air purifiers (AP), physical distancing, and the wearing of masks, can reduce the risk of infection. To quantify the actual effect of precautions, it is not possible in experimental studies to expose subjects to virulent aerosols. Therefore, in this study, we develop a computational fluid dynamics (CFD) model to evaluate the impact of applying the aforementioned precautions in classrooms on reducing aerosol concentration and potential exposure in the presence of index or infected patients. A CFD-coupled Wells–Riley model is used to quantify the infection probability (IP) in the presence of index patients. Different cases are simulated by varying the occupancy of the room (half/full), the volumetric flow rate of the AP, two different locations of the AP, and the effect of wearing masks. The results suggest that using an AP reduces the spread of virulent aerosols and thereby reduces the risk of infection. However, the risk of the person sitting adjacent to the index patient is only marginally reduced and can be avoided with the half capacity of the class (physical distancing method) or by wearing face masks of high efficiencies.

2.
Indoor Air ; 32(11): e13165, 2022 Nov.
Article in English | MEDLINE | ID: covidwho-2136901

ABSTRACT

COVID-19 has highlighted the need for indoor risk-reduction strategies. Our aim is to provide information about the virus dispersion and attempts to reduce the infection risk. Indoor transmission was studied simulating a dining situation in a restaurant. Aerosolized Phi6 viruses were detected with several methods. The aerosol dispersion was modeled by using the Large-Eddy Simulation (LES) technique. Three risk-reduction strategies were studied: (1) augmenting ventilation with air purifiers, (2) spatial partitioning with dividers, and (3) combination of 1 and 2. In all simulations infectious viruses were detected throughout the space proving the existence long-distance aerosol transmission indoors. Experimental cumulative virus numbers and LES dispersion results were qualitatively similar. The LES results were further utilized to derive the evolution of infection probability. Air purifiers augmenting the effective ventilation rate by 65% reduced the spatially averaged infection probability by 30%-32%. This relative reduction manifests with approximately 15 min lag as aerosol dispersion only gradually reaches the purifier units. Both viral findings and LES results confirm that spatial partitioning has a negligible effect on the mean infection-probability indoors, but may affect the local levels adversely. Exploitation of high-resolution LES jointly with microbiological measurements enables an informative interpretation of the experimental results and facilitates a more complete risk assessment.


Subject(s)
Air Pollution, Indoor , COVID-19 , Humans , SARS-CoV-2 , Restaurants , Air Pollution, Indoor/analysis , Respiratory Aerosols and Droplets
3.
Indoor Air ; 32(10): e13110, 2022 Oct.
Article in English | MEDLINE | ID: covidwho-2084619

ABSTRACT

Airborne transmission of disease is of concern in many indoor spaces. Here, aerosol dispersion and removal in an unoccupied 4-bed hospital room were characterized using a transient aerosol tracer experiment for 38 experiments covering 4 configurations of air purifiers and 3 configurations of curtains. NaCl particle (mass mean aerodynamic diameter ~3 µm) concentrations were measured around the room following an aerosol release. Particle transport across the room was 1.5-4 min which overlaps with the characteristic times for significant viral deactivation and gravitational settling of larger particles. Concentrations were close to spatially uniform except very near the source. Curtains resulted in a modest increase in delay and decay times, less so when combined with purifiers. The aerosol decay rate was in most cases higher than expected from the clean air delivery rate, but the reduction in steady-state concentrations resulting from air purifiers was less than suggested by the decay rates. Apparently, a substantial (and configuration-dependent) fraction of the aerosol is removed immediately, and this effect is not captured by the decay rate. Overall, the combination of curtains and purifiers is likely to reduce disease transmission in multi-patient hospital rooms.


Subject(s)
Air Filters , Air Pollution, Indoor , Humans , Air Pollution, Indoor/analysis , Aerosols , Patients' Rooms , Hospitals
4.
J Occup Environ Hyg ; 19(10-11): 646-662, 2022.
Article in English | MEDLINE | ID: covidwho-2037262

ABSTRACT

In light of the COVID-19 pandemic, the importance of protective measures against infectious aerosols has drastically increased, as the transmission of diseases via airborne particles is impacting many aspects of everyday life. The protective measures against such infections are determinant in the operation of schools and kindergartens, hygiene in hospitals and medical facilities, in offices, administrative and production facilities, hotels, and the event industry, among others. To test these protective measures, suitable test aerosols and processes are needed. These aerosols ought to be similar to aerosols exhaled by humans as those carry the pathogens and thus need to be removed from the air or inactivated. The exhaled aerosols of several healthy test subjects were characterized by their particle concentration and size distribution. In previous studies, it was found that exhaled particle concentration varies significantly from subject to subject and most of the particles can be found in the submicron size range. Aerosols technically generated through nebulization were emitted by the generators in particle concentrations several orders of magnitude higher than those exhaled by humans, independent of the aerosol generation method and nebulized fluid. The particle size distribution generated by the two nebulizers used, however, was quite similar to the measured size distributions of the human aerosols, with most of the particles below 1 µm in size. Consequently, the used aerosol generators are not suitable to mimic single individuals as active aerosol sources, but rather to provide a sufficient amount of aerosol similar to human aerosols in size distribution, which can be used in the testing of air purification technologies.


Subject(s)
COVID-19 , Pandemics , Humans , Particle Size , Respiratory Aerosols and Droplets , COVID-19/prevention & control , Nebulizers and Vaporizers
5.
Atmosphere ; 13(5):800, 2022.
Article in English | ProQuest Central | ID: covidwho-1871824

ABSTRACT

Aims: With the ongoing pandemic and increased interest in measures to improve indoor air quality, various indoor air purifiers have become very popular and are widely used. This review presents the advantages and disadvantages of various types of technologies used in air purifiers in terms of reducing microbial contamination. Methods: A literature search was performed using Web of Science, Scopus, and PubMed, as well as technical organizations dealing with indoor air-quality to identify research articles and documents within our defined scope of interest. Relevant sections: The available literature data focus mainly on the efficiency of devices based on tests conducted in laboratory conditions with test chambers, which does not reflect the real dimensions and conditions observed in residential areas. According to a wide range of articles on the topic, the actual effectiveness of air purifiers is significantly lower in real conditions than the values declared by the manufacturers in their marketing materials as well as technical specifications. Conclusions: According to current findings, using indoor air purifiers should not be the only measure to improve indoor air-quality;however, these can play a supporting role if their application is preceded by an appropriate technical and environmental analysis considering the real conditions of its use.

6.
Brazilian Dental Science ; 25(1), 2022.
Article in English | Scopus | ID: covidwho-1847516

ABSTRACT

The neoteric coronavirus outburst has jeopardised the health care system globally. As a result, practising dentistry has severe constraints due to production of aerosols and splatter in a large quantity. Air management gains foremost importance in reducing the transmission of SARS-COV-2 in a dental operatory. A variety of air filtration techniques have been put forth to optimize the air quality by removing the pollutants and pathogens. Amidst the blowing wave of information accessible online and on social media, it is puzzling to identify dependable research data and guidance to equip the operatory to minimize the risk of disease by aerosol, droplet and contact transmission. This paper presents comprehensive review on the different air purification technologies, their mechanism and utility in reducing viral load with the aim of providing information in regards to setting up a dental operatory with reduced risk of disease transmission in the post COVID-19 era. © 2022, Universidade Estadual Paulista, Institute of Science and Technology of Sao Jose dos Campos. All rights reserved.

7.
Int J Environ Res Public Health ; 18(21)2021 11 02.
Article in English | MEDLINE | ID: covidwho-1502421

ABSTRACT

In the wake of the COVID-19 pandemic, an increased risk of infection by virus-containing aerosols indoors is assumed. Especially in schools, the duration of stay is long and the number of people in the rooms is large, increasing the risk of infection. This problem particularly affects schools without pre-installed ventilation systems that are equipped with filters and/or operate with fresh air. Here, the aerosol concentration is reduced by natural ventilation. In this context, we are investigating the effect of large mobile air purifiers (AP) with HEPA filters on particle concentration and their suitability for classroom use in a primary school in Germany. The three tested APs differ significantly in their air outlet characteristics. Measurements of the number of particles, the particle size distribution, and the CO2 concentration were carried out in the classroom with students (April/May 2021) and with an aerosol generator without students. In this regard, the use of APs leads to a substantial reduction of aerosol particles in the considered particle size range of 0.178-17.78 µm. At the same time, the three APs are found to have differences in their particle decay rate, noise level, and flow velocity. In addition to the measurements, the effect of various influencing parameters on the potential inhaled particle dose was investigated using a calculation model. The parameters considered include the duration of stay, particle concentration in exhaled air, respiratory flow rate, virus lifetime, ventilation interval, ventilation efficiency, AP volumetric flow, as well as room size. Based on the resulting effect diagrams, significant recommendations can be derived for reducing the risk of infection from virus-laden aerosols. Finally, the measurements were compared to computational fluid dynamics (CFD) modeling, as such tools can aid the optimal placement and configuration of APs and can be used to study the effect of the spread of aerosols from a source in the classroom.


Subject(s)
Air Filters , COVID-19 , Aerosols , Humans , Pandemics , SARS-CoV-2
8.
Sustain Cities Soc ; 70: 102942, 2021 Jul.
Article in English | MEDLINE | ID: covidwho-1185260

ABSTRACT

INTRODUCTION: The advent of COVID-19 has impinged millions of people. The increased concern of the virus spread in confined spaces due to meteorological factors has sequentially fostered the need to improve indoor air quality. OBJECTIVE: This paper aims to review control measures and preventive sustainable solutions for the future that can deliberately help in bringing down the impact of declined air quality and prevent future biological attacks from affecting the occupant's health. METHODOLOGY: Anontology chart is constructed based on the set objectives and review of all the possible measures to improve the indoor air quality taking into account the affecting parameters has been done. OBSERVATIONS: An integrated approach considering non-pharmaceutical and engineering control measures together for a healthy indoor environment should be contemplated rather than discretizing the available solutions. Maintaining social distance by reducing occupant density and implementing a modified ventilation system with advance filters for decontamination of viral load can help in sustaining healthy indoor air quality. CONCLUSION: The review paper in the main, provides a brief overview of all the improvement techniques bearing in mind thermal comfort and safety of occupants and looks for a common ground for all the technologies based on literature survey and offers recommendation for a sustainable future.

SELECTION OF CITATIONS
SEARCH DETAIL